Commit graph fingerprintd/tests/Ta
Author SHA1 Message Date
afb7496ef6 Fix the poison offset: a released finger was reading as a rejection
PoisonFid takes the payload and offsets to the fid field internally. It was
being handed a span already offset by the payload offset, so the poison landed
at payload+0x20 and the real fid field stayed zero. A frame where the matcher
never ran then looks exactly like a frame where it ran and rejected -- which is
the specific failure this project has recorded three times and is precisely
what the poison exists to prevent.

Visible in a real run: the frames marked REJECTED were 138, 138, 133, 137, 134
against a floor of 136, i.e. every one of them was a finger-RELEASE frame with
nothing on the sensor. Five rejections that never happened.

The two offsets are numerically equal, which is why double-applying is silent,
so the test now pins both directions: poisoning the payload marks the fid
field, and poisoning an already-offset span leaves it zero and misclassifies.

Also adds --rescan=N, which patches common.max_authentication_rescan_times into
the config. The stock budget lets a whole run end with no terminal verdict --
correct for shipping, useless as a measurement, because a wrong-finger control
that never reaches a verdict has not demonstrated a rejection. Forcing 0 makes
every frame terminal. It prints MEASUREMENT ONLY because a rate taken that way
is a per-frame figure with the retry mechanism disabled, and is not a shipping
reject rate.
2026-09-02 19:16:50 +02:00
03023284ba Serve QTEE's storage: the enrolled template loads
The whole storage path now works from the daemon. On the phone, against the
real store:

    listener 0x7000  sb=516096  -> result=0  REGISTERED
    listener 0x2000  sb=25600   -> result=0  REGISTERED
    SET_ACTIVE_GROUP gid=60 path='/data/vendor_de/0/fpdata'
      gpfile READ .../1lPrxAL0vXRvWPeDkW2c off=4096 len=252114
      ...
      CMD 0x2005 -> result=0 rc=1
      templates loaded: 1

QTEE read a 252114-byte enrolled template through our gpfile listener, verified
it, and loaded it. Since QTEE unlinks any container whose keyed integrity tag
fails, a load is proof the framing is right -- the read/write offset split, the
container chunking, and the RPMB anti-rollback read that has to succeed before
QTEE will trust any of it.

RPMB is served too: SECURITY PROTOCOL IN/OUT against the RPMB well-known LUN,
retrying the unit attention the LUN raises once after a reset. Writes are
refused unless asked for, because they advance a counter that cannot be moved
back, and key programming is refused unconditionally.

The store was served READ-ONLY throughout, which is the point. A listener that
serves bytes at the wrong offset does not merely fail: QTEE deletes the
container it cannot verify, and that is an enrolled fingerprint gone. Read-only
makes a wrong build harmless, so it is the default and writing is opt-in.

Two ordering facts, both of which produce -2 with no storage read at all --
indistinguishable from a broken listener:

  * a template reload needs the device init chain to have run FIRST, because
    that chain allocates the per-slot array the reload writes through;
  * SET_ACTIVE_GROUP's second field is a NAMESPACE path, not a filesystem one
    and not the gid again. The trustlet hashes it into the group's directory
    name, so it has to match what the store was written under.

Also: a positive rc is not an error code. ENUMERATE returns the template count
there, and running that through the error table printed "unknown" for a good
answer.
2026-09-02 18:42:20 +02:00
6c4622afff Capture works: idle floor 133, matching the reference measurement
The finger-free path is complete. On the phone, from a cold start:

    client env -> loader -> trustlet -> config -> sensor rail -> init chain
    calibrating the idle floor (5 samples)
      idle 1/5: rc=-11 metric=133
      ...
    idle floor = 133, finger threshold = 266

133 is the number the journal records for this sensor, so the port reproduces
the reference measurement rather than merely producing one.

Two things had to be right at once, and the first attempt had neither.

The memory region: CAPTURE_IMAGE reads an output-buffer pointer out of
payload+0x00, and QTEE only patches an address there if the location is named
in embeddedBufOffsets and the region handed over in an object slot. The
instrumented dump shows it working -- payload+0x00 came back holding
0x088db98000 -- which is what made the remaining failure legible instead of
mysterious.

And two fields inside the capture payload that an all-zero request leaves
unset: a frame count at +0x0c and a branch selector at +0x10. Selector 0
returns metric 0. Sending zeros gets -201 with the region correctly attached,
which reads exactly like a broken region and is not one. They are named
constants now, with the note that the metric is PER FRAME so a threshold
calibrated at one frame count means nothing at another.

The flags word at payload+0x18 stays past the declared length of 0x14 on
purpose: the trustlet range-checks that length to exactly 0x14 and reads the
flags anyway.

--verbose keeps the region and reqOut dumps, which is what turned this from
guesswork into reading.
2026-09-02 18:27:35 +02:00
2648e46d43 Load the trustlet and configure it
On the phone, end to end from the daemon:

    lookupTA('focal64') -> result=23 (nothing to unload)
    trustlet loaded from /lib/firmware/focal64.mbn, distName='fingerprint'
    config /lib/firmware/fingerprintd.json: 349 bytes
      CMD 0x100d -> result=0 rc=0 (Success)
      CMD 0x2005 -> result=0 rc=0 (Success)

The config is the one fp6fpcfg.py --daemon generates, so the reduction of nine
hand-edited ffcfg files to one generator is confirmed against the trustlet
rather than only against the files it replaced.

A stale instance is unloaded before loading, which is what stops a crashed
experiment costing a reboot; result=23 is the clean-slate answer.

The request envelope moves into Fingerprintd:Ta with the rest of the layouts:
command id at +0, declared length at +4, payload at +0x10, and on the way back
the trustlet's own rc at +8 and the capture metric at +0x0c. Both are HEADER
fields ahead of the payload -- the metric has been miscalled "payload+12" in
this project's notes, and every recorded finger number depends on reading it
where it actually is.

ENUMERATE answering rc=0 is correct here and not a regression: no group is
active and no storage listeners are registered yet, so there are no templates
to count.
2026-09-02 18:19:26 +02:00
ffad29ba4e Port the trustlet command surface, and pin the counting rule to recorded runs
Fingerprintd:Ta is the second core module: request payloads, response fields,
the error table, and the rule that decides what a frame meant. Payload building
and response reading only -- no TEE, no transport.

Very little of this is guessable, so each constant carries where it came from.
Three were found only because QTEE recorded a fault naming the instruction that
read them:

  * the event context's scan-slot count at +712, which do_enroll branches on to
    skip the entire slot loop -- an all-zero payload logged "groups->,
    results->" and read exactly like a gate failing deep in the trustlet, when
    it was zero iterations;
  * CAPTURE_IMAGE's flags at payload+0x18, without which preprocessing, the
    classifier and the enrol grouper never run at all, whatever is on the
    sensor;
  * SYNC_STATISTICS, whose absence leaves g_statistics NULL so the first enrol
    frame that gets far enough takes a data abort and every later command
    answers -90.

The verdict rule gets the most attention because it was mislabelled three times
before the comparison producing it was read. A frame is one of three things and
only the third is a verdict: the poison intact means the matcher never ran,
rc=-11 means not identified yet with attempts remaining, and only rc=0 carries
a match or a rejection. The poison exists because a zero-initialised buffer
cannot tell a released finger from a rejected one.

The tests are in two halves that cannot prop each other up. Explicit wire
conditions pin the classifier; three recorded runs pin the counting policy,
which is what actually went wrong. In the stock-budget run 31 of 48 frames
answered "not identified yet" and every frame that carried an image matched --
counting those 31 as attempts turns 8-for-8 into 8-of-39 and reads as a flaky
sensor. The wrong-finger control pins zero false accepts.

Fixtures are verdict-line excerpts, not the 40 KB transcripts, which are thick
with the device's SFS container names the test has no use for.

Verified by mutation: classifying -11 as a rejection, dropping SYNC_STATISTICS
from the init chain, and forgetting the +0x10 response payload offset each fail
the suite.
2026-09-02 16:46:00 +02:00